STATUS
This is a
Government of India laboratory with NABL accreditation in accordance with the
standard ISO / IEC 17025:2005 in major areas having recognition from the
following reputed organizations as their registered testing laboratory.
The details of testing at various laboratories and Electro-Technical calibration are accredited by National Accreditation Board for Testing & Calibration Laboratories, Department of Science & Technology, Government of India and are appended below .
Chemical Testing
Mechanical Testing
Electrical Testing
Non-Destructive Testing
Electro-Technical Calibration
Mechanical Calibration
Thermal Calibration
NABL Certificate No. T-0147
|
Sl.No. |
Product/Material of test |
Specific Test Performed |
Range of Testing / Limits of Operation / Limits of Detection |
| 1. | Steel |
Carbon Sulphur PhosphurusSilicon
Molybdenum Nickel Chromium Tungsten |
0.05 to 2.5% 0.01 to 0.5% 0.01 to 1%
0.1 to
2%
0.1 to
15.0%
0.1 to
4% 0.1 to 30% 0.05 to 30% 0.1 to 20% |
| 2. | Copper & Copper-Alloys |
Copper Zinc Tin Manganese Nickel Iron Silver Antimony Phosphorous Aluminium Arsenic Bismuth Silicon Mercurous nitrate test |
40 to 99.99% 0.01 to 15% 0.1 to 20% 0.05 to 5% 0.1 to 5.0% 0.01 to 5% 0.1 to 2% 0.1 to 10% 0.01 to 1% 0.1 to 11% 0.01 to 0.3% 0.01 to 1% 0.01 to 5% For determination of internal crack of the sample |
| 3. | Aluminium & Aluminium Alloys |
Aluminium Copper Lead Zinc Iron Antimony Nickel Silicon Chromium Manganese Magnesium Titanium Vanadium Silver Arsenic Bismuth |
40 to 99.99% 0.1 to 10% 0.1 to 10% 0.01 to 10% 0.01 to 5% 0.01 to 1% 0.01 to 2% 0.01 to 11% 0.01 to 2% 0.01 to 5% 0.02 to 15% 0.1 to 2% 0.1 to 2% 0.01 to 2% 0.01 to 0.5% 0.01 to 2% |
| 4. | Tin & Tin Alloys |
Tin Copper Lead Zinc Antimony Iron Silver Bismuth Arsenic Cadmium Aluminium Nickel |
40 to 99.99% 0.1 to 5% 0.1 to 50% 0.01 to 10% 0.01 to 5% 0.01 to 5% 0.01 to 2% 0.05 to 2% 0.01 to 0.5% 0.01 to 1.5% 0.05 to 5% 0.01 to 5% |
| 5. | Zinc & Zinc Alloys |
Zinc Bismuth Copper Tin Iron Aluminium Magnesium Silver Antimony Cadmium Lead Nickel Arsenic |
40 to 99.99% 0.01 to 20% 0.1 to 10% 0.01 to 2% 0.01 to 5% 0.01 to 2% 0.1 to 10% 0.01 to 2% 0.05 to 2% 0.01 to 5% 0.1 to 15% 0.1 to 5% 0.01 to 0.2% |
| 6. | Lead & Lead Alloys |
Lead Tin Antimony Nickel Cobalt Cadmium Zinc Copper Bismuth Iron |
40 to 99% 0.1 to 40% 0.1 to 10% 0.01 to 10% 0.01 to 5% 0.01 to 5% 0.01 t0 5% 0.05 to 4% 0.01 to 2.5% 0.01 to 5% |
| 7. | Magnesium & Magnesium Alloys |
Magnesium Manganese Nickel Tin Aluminium Silicon Iron Copper Zinc |
40 to 99% 0.01 to 5% 0.1 to 2% 0.1 to 5% 0.1 to 4.5% 0.01 to 2% 0.01 to 2% 0.01 to 5% 0.05 to 10% |
| 8. | Synthetic Detergents |
Active Ingredients Active Alkalinity Total Phosphate Matter Insoluble in Water STPP & Pyrophosphate |
1 to 25% -50 ml N/10 HCl -1 to 20% 0.1 to 5%
0.01 to 10% |
| 9. | Metallic Coatings |
Zinc Coatings
Nickel Coating
Copper coating Anodised Coating Tin Coating |
Amount of Zn Coating -5 to 1000 g/mm² Thickness of coating 5 to 100 micron Uniformity of coating
Thickness of coating 5 to 100 micron -do- -do- -do- |
| 10. | Paints |
Weight per litre Consistency Preparation of Panel FinishDrying time Colour Water content Flash Point Weight Opacity Fastness to light Scratch Hardness Flexibility & Adhesion Gloss |
0.7 to 3.5 Kg. -- -- -- -- -- 0.1 to 10% Ambient to 80ºC 10 to 300 Sqmt/10 lt. -- -- -- 5 to 100 |
NABL Certificate No. T-0087
|
Sl.No. |
Product/Material of test |
Specific Tests Performed |
Limits of its Operation / Range of testing / Limits of detection |
|
1. |
Metallic, Non-Metallic Products/ Raw materials
|
Brinell Hardness test |
15.625-3000 Kgf |
|
Rockwell(B&C) Scale |
100 & 150 Kgf |
||
|
Vickers Hardness Test |
5.0-50 Kgf |
||
|
Tensile
test for
Ferrous & Non-ferrous Metal Rubber FRP |
0-1000 KN 0-10 KN
|
||
|
2. |
Bend Test | upto 180o | |
| Rebend Test | 135o -157o | ||
| Wedge Load Test | Upto M16 | ||
| Flattening Test |
0-1000KN |
||
| Proof pressure test of Valves, Pipes & fittings |
0-50 Kg/Cm2 |
||
|
3.
4.
5. |
Brick /
Concrete Cubes /
Mechanical Jacks
Metallic & Non-metallic products / Raw Materials |
Compressive strength
|
Upto 950 KN |
| Proof load test | Upto 950 KN | ||
|
Flexural / Cross Breaking strength |
Upto 950 KN | ||
| Microstructure Analysis (Phase identification & volume fraction) | Mag:500 | ||
| Depth of Decarburisation | Mag: 100 | ||
| Determination of Case Depth | Mag: 100 |
NABL Certificate No. T- 0099
|
Sl.No. |
Product / Material of test |
Specific Tests Performed |
Limits of its Operation / Range of testing / Limits of detection |
|
1. |
LAMPS (Tungsten filament General service Electric and Miscellaneous Electric Lamps) |
a. Markings |
-- |
|
b. Dimensions |
0-200mm |
||
|
c.Cap Dimensions |
Standard Gauges as per IS:9206-1979 |
||
d.Torsion Test |
Upto 4 Nm |
||
|
e.Insulation Resistance |
0 to 100MΩ, 500V DC |
||
|
f. Solder |
0-200mm |
||
|
g. Initial Rating Test |
Wattage: 10,15,25,40,60,100,150, 200,300W Voltage: 110,230,240,250V |
||
|
h. Life performance |
- do- |
||
|
i. Lamp Cap. Temp. RiseTest |
Upto 1350 C |
||
|
2. |
DRY BATTERIES : Multi-purpose / Heavy Duty Dry Batteries |
a. Marking |
--- |
|
b. Dimension |
0-200mm |
||
|
c. Material & construction |
---- |
||
|
d. Initial life test |
For R6, R14, R20 |
||
e.Delayed life test |
R6, R14, R20 |
||
|
f. Delayed life test under dry heat condition |
Upto 95%, RH |
||
|
g. Leakage test |
For R6, R14, R20 size |
||
|
3. |
Electrical Fans and Regulators |
a.Air Delivery |
Upto 500m/minute |
|
b. Temp. Rise |
Upto 1350 C |
||
c. Leakage current |
300/3000 µA |
||
|
d. High voltage |
Upto 6KV AC & 12DC |
||
|
e. Insulation resistance |
Upto 100 MΩ |
||
|
f. Starting |
|
||
|
g. Speed and input |
0-60,000 RPM 300W/1500 W |
||
|
h. Earthing connection |
0-500A |
||
|
i. Protection against electric shock |
-- |
||
|
j. Moisture resistance for regulators only |
Upto 95% & RH 98% |
||
|
k. Mechanical strength for regulators only |
0.2 to 1 Nm |
||
|
l. Suspension System |
1000Kg & 500Kg cm |
||
|
m. Cord Grip |
0-100 Nm |
||
|
n. Creepage Distance & Clearance |
0-200mm |
||
|
o. Mechanical endurance for regulators |
2500 operations |
||
|
4. |
PVC insulated cables for working voltage Upto and including 1100 volts |
a) Tests on Conductor |
|
|
i) Annealing test |
-- |
||
|
ii) Tensile test |
Upto 10 KN |
||
|
iii) Wrapping test for Al conductor |
-- |
||
|
iv) Resistance test |
0 to 11Ω |
||
|
b) Test for overall Dimensions and Thickness of insulation and sheath |
0 – 200 mm |
||
|
c) Physical tests for insulations and sheath |
|
||
|
i) Tensile strength and Elongation at break |
Upto 10 KN |
||
|
ii) Loss of Mass test |
Upto 100 ºC, Balance, L.C.O.1 mg. |
||
|
iii) Thermal Ageing in air |
Upto 100ºC |
||
|
iv) Shrinkage test |
Upto 250ºC |
||
|
v) Heat Shock test |
Upto 250ºC |
||
|
vi) Hot Deformation test |
Upto 100 ºC |
||
|
d) Insulation Resistance |
10 MΩ to 109 MΩ |
||
|
e) High Voltage Test (Water Immersion Test ) |
Upto 2 KV DC & 6 KV AC ( r.m.s ) |
||
|
f) Flammability Test |
-- |
||
|
g) Cold Bend Test |
As per table 1 & 2 of IS : 5831-84 |
||
|
h) Cold Impact Test |
Table 1&2 of IS:5831-84 |
||
|
i) Additional Ageing Test |
16.6 of IS:694-90 |
||
|
5. |
PVC insulated (Heavy Duty ) Electric Cables for working voltage upto and including 1100 volts.As per IS :1554 ( Part I ) - 1998 and IS : 3975-1998 |
A) Tests on Conductor |
|
|
i) Annealing test |
-- |
||
|
ii) Tensile test for Al |
Upto 10KN |
||
|
iii) Wrapping test for Al |
-- |
||
|
iv) Per sulphate test |
-- |
||
|
v) Conductor resistance test |
0 to 11Ω |
||
|
B) Test for Overall Dimensions and Thickness of insulation and sheath |
0 – 200 mm |
||
|
C) Physical tests for insulations and outer sheath |
-- |
||
|
i) Tensile strength and Elongation at Break |
Upto 10 KN |
||
|
ii) Loss of Mass test |
Upto 100 ºC balance L.C.O.1 mg. |
||
|
iii) Thermal Ageing in Air |
Upto 100 ºC |
||
|
iv) Shrinkage test |
Upto 250 ºC |
||
|
v) Heat shock test |
Upto 250 ºC |
||
|
vi) Hot Deformation |
Upto 100 ºC |
||
|
vii) Thermal Stability |
Upto 250 0 C |
||
|
D) Test for armouring wires & strips
a) Dimension of armouring material |
0 – 200 mm |
||
|
b) Tensile strength and elongation at Break |
Upto 1000 KN |
||
|
c) Torsion test on galvanized steel strip for armouring |
Upto 4.0 mm Dia Steel wire |
||
|
d) Winding test on galvanized strip for armouring |
-- |
||
|
e) Uniformity of steel coating armour |
-- |
||
|
f) Mass of zinc coating on steel and armour |
-- |
||
|
g) Resistivity test of armour wires and strips and conductance test of armour ( wires and strips ) |
-- |
||
|
E) Insulation Resistance test |
10 MΩ to 109 MΩ |
||
|
F) High Voltage Test (Water Immersion Test ) |
Upto 2 KV DC & 6KV AC (r.m.s.) |
||
|
G) High Voltage test at Room Temperature |
Upto 6 KV AC |
||
|
H) Flammability test |
--
|
||
|
|
|
I) Cold bend test |
As per table 1 & 2 of IS: 5831/84 |
|
|
|
J) Cold Impact Test |
As per table 1 & 2 of IS: 5831/84 |
|
6. |
LEAD-ACID
STORAGE
BATTERIES |
a) Physical Examination |
-- |
| b) Dimension & Layout |
Up to 525 mm |
||
| c) Marking |
-- |
||
| d) Air Pressure Test |
# Up to 70 cm |
||
| e) Capacity Test |
Up to 200 AH |
||
| f) Vibration Test |
Up to 200 AH |
||
| g) HRD Test at normal Temp. |
Up to 1000 A |
||
| h) HRD Test at Low Temp. |
Up to 1000 A |
||
| i) Retention of charge |
Up to 200 AH |
||
| j) Resistance to overcharge |
Up to 200 AH |
||
| k) Life Test |
Up to 200 AH |
||
| l) Storage Test |
Up to 200 AH |
|
7. |
STATIONARY CELLS AND BATTERIES, LEAD ACID TYPE :
|
a)
Verification of construc- tional requirements |
-- |
| b) Verification of Marking |
-- |
||
| c) Verification of Dimensions |
Up to 715 mm |
||
|
d) Test
for capacity/ Voltage
drop during discharge |
Up to 800 AH |
||
|
e)
Ampere-hour and Watt- hour efficiency Test |
Up to 800 AH |
||
| f) Test for loss of capacity |
Up to 800 AH |
||
| g) Endurance Test |
Up to 800 AH |
NABL Certificate No.T-0085
|
Sl.No. |
Product/Material of test |
Specific Tests Performed |
Limits of its Operation / Range of testing / Limits of detection |
|
1. |
Ferrous products like castings, forgings, welded and fabricated products. |
Radiographic Testing by using X-ray |
Range : Equivalent to steel of 60 mm thickness. |
|
2. |